PRC has designed developed a complete solution for heavy presses Pneumatic manufacturers users for their pressure controlling problems It is very challenging to maintain predetermined pressure in the presses to produce a good quality product Many times product is rejected due to increase or decrease in pressure which costs to manufacturer very high
Independent electronic module for die cushion counter balance
Due to manually controlled pressure by regulator of cushion counter balance the following drawbacks has removed by using above automatic pressure controlling system
Cushion
- Production Was Less Due To High Pressure Setting Time
- Production Rejection Was High Due To Not Exact Setting Of
- Pressure As Components Were Required
- Hard In Machining High Cushion Impact On Slide Due To
- High Cushion Pressure
- Not Proper Shape of Component Due To Less Cushion Pressure
- Counter balance
- Motor Taking High Current When Balance Pressure of
- Counter Is High Motor Taking High Current When Balance Pressure of
- Counter Is Low Slide Coming Down May Cause Of Accident Due To
- Not Proper Counter Balance Pressure As Per Slide And Die Weight
- Automatic pressure controller
- Easy To Set Pressure for both Cushion and Counter Balance Set Both Pressure as Per Components Requirement Once
- and Forget It High Production and No Rejection Less Power Consumption Improve Product Quality And Do Safe Production
Features
- Designed to suit the Indian environmental conditions
- Inexpensive in comparison to other solutions
- Precision accurate pressure setting
- Wide application range
- Reliable dependable
- User friendly with standard warranty
- Customized solutions available
- Standard Specifications
- Application Suitable for presses Die Cushion Counter Balance
- Machine controller HMI touch screen
- Screen size 43
- ADC 24 bit
- Power supply 220 V AC 50 Hz 10
- Front panel Touch screen ON OFF push button
- On screen display Real time clock with date provided
- Settable parameters High low limits for die cushion counter balance separately
- Protection Password protection
- Data storage Through built in memory
- Data transfer Through USB device
- Rear panel Phoenix connectors provided to connect input source
- Measurement Measuring pressure in Bar
- Analog Input Two Analog inputs for Strain Gauge type Pressure Transducer
- Digital Inputs 8 Digital Inputs
- Outputs 8 Relay outputs for Machine operation
- Function mode Auto Manual
- Calibration Simple calibration procedure for Pressure Transducer
- Keypad Menu driven on screen data feeding
- Controller Two independent controllers for Cushion Counter Balance